Data Sheet - Series 6 Miniature Position Transducers

With FlexSignal™ Integrated Signal Conditioning

Shaded characteristics are verified during production and test. All others are for REFERENCE and information only.

Key Features

  1. 85-Inch (2159-mm) Maximum Travel (Model 62)
  2. Choice of FlexSignal™ Analog and Digital Output Signals (Factory Set)
  3. AccuTrak™ Threaded Drum For Enhanced Repeatability
  4. DirectConnect™ Sensor-To-Drum Technology = Zero Backlash, No Torsion Springs or Clutches
  5. NEMA 4 / IP 66 Environmental Protection
  6. Flexible Mounting Bases
  7. Industrial Operating Temperature Ranges
  8. Choice of Electrical Terminations: MIL-C-5015, DIN 45326, Lemo, flying leads

Electrical Outputs - Voltage Divider

VOLTAGE DIVIDER (hybrid or conductive plastic precision potentiometer)
Item 1-turn sensor 3-, 5-, and 10-turn sensors
Resistance: Value, Tolerance 5K ohms, ±10% 5K ohms, ±10%
Travel: Electrical 340° 1080° (3-turn), 1800° (5-turn), 3600° (10-turn)
Travel: Mechanical 360° continuous 1080° (3-turn), 1800° (5-turn), 3600° (10-turn) (+15° -0°)
Mechanical Life 5 million shaft revolutions min 5 million shaft revolutions min
Power Rating 1.0 W at 158° F (70° C); 50 VDC / 12 mA max 2.0 W at 158° F (70° C); 50 VDC / 12 mA max
Independent Linearity Error ±1.0% max per VRCI-P-100A ±0.25% max per VRCI-P-100A
Output Smoothness 0.1% max 0.051% max
Insulation Resistance 1000 Mohms min at 750 Vrms 1000 Mohms min at 750 Vrms
Dielectric Strength 750 Vrms min 1000 Vrms min
Resolution infinite signal infinite signal
Operating Temperature -40° to 185° F (-40° to 85° C) -40° to 185° F (-40° to 85° C)
Shock / Vibration 100 g for 6 ms / 10 to 500 Hz at 10 g 100 g for 6 ms / 10 to 2000 Hz at 15 g
Thermal Coefficient ±0.01%/°C max ±0.01%/°C max

The potentiometer type of a specific potentiometer-based position transducer partnumber is designated by the 5th position of the part number counting left to right. Example: 60-11-5222 contains a 1-turn potentiometer while 60-60-8633 contains a 10-turn potentiometer ("0" indicates a 10-turn potentiometer).


Electrical Connection
Code 1 (wire)
red
black
white
Code 2 (pin)
A
B
C
Code 3 (pin)
1
2
3
Code 4 (pin)
1
2
3
Signal
input, V+
ground, common, V-, S-
output, signal, S+

Electrical Outputs - Low-Level Bridge

LOW-LEVEL BRIDGE (B Circuit / Strain Gage Compatible)
Item Value
Supply Voltage 7 to 40 VDC max
Supply Current 20 mA max
Reverse Polarity Protection yes
Increasing/Decreasing Output Options yes
Output Signal 0.2 mV/V to 3.75 mV/V at 24 VDC supply voltage
Zero Adjust 0% to 100% of range (adjustable output via 2 x trim potentiometers)
Span Adjust see Typical Outputs table below (adjustable output via 2 x trim potentiometers)
Independent Linearity Error see Voltage Divider specification above
Insulation Resistance 1000 Mohms min
Resolution infinite signal
Operating Temperature -40° to 185° F (-40° to 85° C)
Thermal Coefficient ±0.01%/°C max

Typical Outputs
Supply Voltage (VDC)
7
12
24
Min Span (mV)
4.92
4.92
4.92
Max Span (mV)
20.5
41
90
Sensitivity Range (mV/V)
0.7 to 2.928
0.41 to 3.42
0.205 to 3.75

Electrical Connection
Code 1 (wire)
red
black
white
green
Code 2 (pin)
A
B
C
D
Code 3 (pin)
1
2
3
4
Code 4 (pin)
1
2
3
4
Signal
V+
V-
S+
S-, ground

To change the output signal's range, follow these steps:

  1. Remove the 2X sealing screws labeled Z and S to reveal the zero and span trim potentiometers.
  2. Extend the displacement cable to the desired start location and adjust the zero trim potentiometer until you get the desired electrical output.
  3. Extend the displacement cable to the desired finish location and adjust the span trim potentiometer until you get the desired electrical output.
  4. Repeat steps 2 and 3.
  5. Replace the 2X sealing screws.

Electrical Outputs - Voltage Conditioner

VOLTAGE CONDITIONER (unregulated input)
Item Unipolar (0-5 VDC, 0-10 VDC, Etc.) Bipolar (±5 VDC, ±10 VDC, Etc.)
Supply Voltage 7 to 40 VDC for 0-5 VDC
12 to 40 VDC for 0-10 VDC
12 to 40 VDC for ±5 VDC
22 to 40 VDC for ±10 VDC
Supply Current 20 mA max 20 mA max
Reverse Polarity Protection yes yes
Increasing/Decreasing Output Options yes yes
Output Signal (User Adjustable) 0-5 VDC, 0-10 VDC, 5-0 VDC, 10-0 VDC, and user-adjustable values (adjustable output via 2 x trim potentiometers) ±5 VDC, ±10 VDC, and user-adjustable values (adjustable output via 2 x trim potentiometers)
Zero Adjust 0% to 100% of range 0% to 100% of range
Span Adjust 20% to 65% at 7 VDC supply
5% to 95% at 40 VDC supply
20% to 65% at 7 VDC supply
5% to 95% at 40 VDC supply
Independent Linearity Error see Voltage Divider specification above see Voltage Divider specification above
Insulation Resistance 1000 Mohms min 1000 Mohms min
Resolution infinite signal infinite signal
Operating Temperature -40° to 185° F (-40° to 85° C) -40° to 185° F (-40° to 85° C)
Thermal Coefficient ±0.01%/°C max ±0.01%/°C max

Electrical Connection
Code 1 (wire)
red
black
white
green
Code 2 (pin)
A
B
C
D
Code 3 (pin)
1
2
3
4
Code 4 (pin)
1
2
3
4
Signal
V+
V-
S+
S-, ground

To change the output signal's range, follow these steps:

  1. Remove the 2X sealing screws labeled Z and S to reveal the zero and span trim potentiometers.
  2. Extend the displacement cable to the desired start location and adjust the zero trim potentiometer until you get the desired electrical output.
  3. Extend the displacement cable to the desired finish location and adjust the span trim potentiometer until you get the desired electrical output.
  4. Repeat steps 2 and 3.
  5. Replace the 2X sealing screws.

Electrical Outputs - 4-20 mA

4-20 mA (2-wire current transmitter)
Item Value
Supply Voltage 12 to 40 VDC with reverse polarity protection
Supply Current 35 mA max
Output Signal 4-20 mA (user adjustable) with increasing and decreasing output options
Zero Adjust 0 to 5% of range (adjustable output via 2 x trim potentiometers)
Span Adjust 50 to 100% of range (adjustable output via 2 x trim potentiometers)
Independent Linearity Error see Voltage Divider specification above
Insulation Resistance 1000 Mohms min at 750 Vrms
Resolution infinite signal
Operating Temperature -40° to 185° F (-40° to 85° C)
Thermal Coefficient ±0.01%/°C max
A Note on Load Resistance in 4-20 mA Current Loops - The maximum load resistance or loop resistance is the maximum resistance of all the loads that are connected in series with the circuit. This includes all instrumentation equipment such as power supply and multimeter. The maximum load resistance (RLmax) depends on 2 factors: the voltage supply (Vps) and the maximum loop current (Iloop). For the Series 6 4-20 mA circuit, RLmax = (Vps - 11.6) / Iloop

Example:

    Vps = 24 V
    Iloop = 30 mA
    RLmax = (24 - 11.6) / 30 = 0.413 Kohms

Electrical Connection
Code 1 (wire)
red
black
Code 2 (pin)
A
B
Code 3 (pin)
1
2
Code 4 (pin)
1
2
Signal
V+
V-

To change the output signal's range, follow these steps:

  1. Remove the 2X sealing screws labeled Z and S to reveal the zero and span trim potentiometers.
  2. Extend the displacement cable to the desired start location and adjust the zero trim potentiometer until you get the desired electrical output.
  3. Extend the displacement cable to the desired finish location and adjust the span trim potentiometer until you get the desired electrical output.
  4. Repeat steps 2 and 3.
  5. Replace the 2X sealing screws.

Electrical Outputs - Digital

DIGITAL (incremental optical encoder (quadrature))
Item Standard Resolution High Resolution
Power Requirement 5 ±0.50 VDC 5 to 26 VDC
Supply Current 29 mA max at 5 VDC 35 mA max at 5 VDC
Logic Output open collector and 3.3 Kohm pull-up resistor (TTL) open collector with Schmitt trigger and 10 Kohm pull-up resistor (push-pull differential line driver)
Power Consumption 145 mW max, 3.86 mA sink current at 0.40 VDC 150 mW max, 16 mA sink current at 0.40 VDC
Travel: Electrical, Mechanical 360° continuous 360° continuous
Mechanical Life 100 million shaft revolutions min 100 million shaft revolutions min
Resolution 1200 quadrature pulses per revolution 8192 quadrature pulses per revolution
Output 2-bit (quadrature) code, A leads B by 90° w/CW 2-bit (quadrature) code, A leads B by 90° w/CW
Operating Temperature 14° to 185° F (-10° to 85° C) -4° to 212° F (-20° to 100° C)
Shock / Vibration 100 g for 6 ms / 5 to 2000 Hz, 20 g 50 g for 11 ms / 50 to 500 Hz at 20 g

Electrical Connection
Resolution Pin/Wire Assignment
Standard Sensor Pin
-
-
-
-
Code 1 (wire)
orange
white/orange
blue
white/blue
Code 2 (pin)
A
B
C
D
Code 3 (pin)
1
2
3
4
Code 4 (pin)
1
2
3
4
Signal
+5 VDC
ground
channel A
channel B
High Sensor Pin
1
2
3
4
5
6
7
8
9
10
Code 1 (wire)
red
gray
brown
green
blue
orange
yellow
white
purple
black
Code 2 (pin)
A
B
C
-
D
-
E
-
-
F
Code 3 (pin)
1
2
-
-
4
-
3
-
-
-
Code 4 (pin)
1
2
3
-
4
-
5
-
-
6
Signal
common
+VDC
Z
Z'
B
B'
A
A'
N/C
case

Nominal Resolution by Model Number (Digital)
Model inches mm Standard Resolution# High Resolution#
pulses/in pulses/mm pulses/in pulses/mm
60-35 21.25 540 278 11 1895 75
61-45 30.00 762 197 8 1344 53
62-55 42.50 1080 140 6 954 37.6
62-60 85.00 2159 140 6 954 37.6

# after quadrature decode by user

Other Specifications

Case/Drum Materials precision-machined, anodized 2024 aluminum
Displacement Cable 0.018-inch (0.46-mm) dia., 7-by-7 stranded stainless steel, 40-lb (177-N) min breaking strength
Displacement
Cable Hardware
1 each of 300196 loop sleeve, 300292 copper sleeve, 300688 ball-end plug, 300495 pull ring, 160026 brass swivel, and 301003 nickel swivel; all items provided uncrimped
Nominal Mass Model 60: 6 oz (170 g), Model 61: 8 oz (227 g), Model 62: 11 oz (312 g)
Environmental Sealing NEMA 4 / IP 66

Model Numbers and Cable Tension

Model Range Nominal Displacement Cable Tension Range (Full Retraction to Full Extraction)
inches mm Opt 5 Opt 6 Opt 7 Opt 8
oz. N oz. N oz. N oz. N
60-11 4.00 102 4 to 8 1 to 2 5 to 12 1 to 4 12 to 20 3 to 6 28 to 55 7 to 16
60-25 13.50 343 7 to 20 2 to 6 12 to 28 3 to 8 18 to 53 5 to 15 30 to 134 8 to 37
60-35 21.25 540 5 to 12 1 to 3 7 to 19 2 to 5 12 to 33 3 to 9 14 to 79 4 to 22
61-45 30.00 762 - - 5 to 12 1 to 3 8 to 23 2 to 6 9 to 60 3 to 17
62-55 42.50 1080 - - 4 to 14 1 to 4 7 to 17 2 to 5 8 to 41 2 to 11
62-60 85.00 2159 - - - - - - 15 to 45 4 to 13

Bolded entries are standard cable tension.

Displacement Cable Maximum Acceleration by Model Number

Model Max Cable Acceleration (g's)
Opt. 5 Opt. 6 Opt. 7 Opt. 8
60-11 8 10 23 69
60-25 55 65 109 165
60-35 30 40 75 70
61-45 - 56 72 95
62-55 - 18 31 45
62-60 - - - 15

Ordering Codes

Order Code Format Description
ab-cd-efgh position transducer
Example: 60-11-6281 (Model 60-11 (Series 60, 4-in (102-mm) range), cable tension: Opt. 6, bridge circuit, base: big foot (60/61), and flying leads)

Variable Value Description
ab-cd _ _-_ _ _ _ size and range (model number)
e 5 cable tension: Opt. 5
6 cable tension: Opt. 6
7 cable tension: Opt. 7
8 cable tension: Opt. 8
f 1 voltage divider
2 bridge circuit - factory preset to 0-10 mV (increasing output), adjustable output via 2 x trim potentiometers
3 bridge circuit - factory preset to 10-0 mV (decreasing output), adjustable output via 2 x trim potentiometers
4 voltage conditioner - factory preset to 0-5 VDC (increasing output), adjustable output via 2 x trim potentiometers
5 voltage conditioner - factory preset to 5-0 VDC (decreasing output), adjustable output via 2 x trim potentiometers
6 4-20 mA (increasing output), adjustable output via 2 x trim potentiometers
7 20-4 mA (decreasing output), adjustable output via 2 x trim potentiometers
8 digital (standard resolution, quadrature)
9 digital (high resolution, quadrature)
g 2 base: standard (60); pn 160015-1
3 base: standard (61); pn 160015-3
4 base: standard (62); pn 160015-5
C base: standard (60) with RoundAbout™ cable guide
D base: standard (61) with RoundAbout™ cable guide
E base: standard (62) with RoundAbout™ cable guide
h 1 FOR f = 1 to 8 > electrical termination: flying leads (4-conductor white Teflon cable with 22 AWG flying leads, 60-in (1524-mm) min length, 0.163 in (4.14 mm) nominal diameter)

FOR f = 9 > electrical termination: flying leads (10-conductor dark gray PVC cable with 24 AWG, 60-in (1524-mm) min length, 0.250 in (6.35 mm) nominal diameter, -20° to +80° C operating temperature range)
2 electrical termination: MS3101E-14S-6PF42-based sealed bulkhead electrical connector and mating 300853 electrical connector (MS3106F-14S-6S)
3 electrical termination: Lemo EGG.0B.304.CLL bulkhead electrical connector and mating Lemo FGG.OB.304.CLAD52 electrical connector
4 electrical termination: DIN 45326 sealed (per IP68) bulkhead electrical connector and mating electrical connector

Drawing

RoundAbout™ cable guide

Related Products

Part Number Description
160001-01 installation kit

For crimping of hardware to displacement cable, consider the 160001-01 installation kit.

Need something not shown? Complete a Custom Solution Request.

All dimensions are REFERENCE and are in inches [mm] • Data Sheet Series 6 Rev. -


Position Measurement Newsletter

Forward This Page to a Friend

Firstmark Controlsinfo@Firstmarkcontrols.com
An ISO9001:2000/AS9100B-Compliant Company
1176 Telecom Drive • Creedmoor, NC 27522 USA
Phone: 1-919-956-4203 • Fax: 919-682-3786 • Toll Free: 1-866-912-6232

Business hours: Mon-Fri, 8:00am to 5:00pm (Eastern time)
All specifications subject to change without notice.
© 1996-2008 Firstmark Controls All rights reserved.

top Newsletter   •   News   •   Representatives   •   Request Literature   •   CAD Models   •   Calculators top